Point-to-Point Lighting Calculator

An offset point is farther from the source and receives the ray obliquely. Combining inverse-square distance and cosine incidence gives I×height/d³ for a horizontal plane. The direction angle is reported so that the matching candela value can be selected from actual photometric data.

Your lighting inputs

m
m
cd

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Distance d = √(height²+offset²); horizontal E = I × height ÷ d³.

Calculate one luminaire’s direct horizontal illuminance contribution at an offset point.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Intensity must correspond to the ray toward the point. This does not read an IES file, calculate reflections or complete a street/parking/sports lighting design.

Direct horizontal illuminance away from the fixture axis

An offset point is farther from the source and receives the ray obliquely. Combining inverse-square distance and cosine incidence gives I×height/d³ for a horizontal plane. The direction angle is reported so that the matching candela value can be selected from actual photometric data.

Outdoor, street, baseball field and parking-lot lighting normally involve several fixtures, glare constraints and defined grids. This single-point model is a building block, not a complete site design. Do not use peak center intensity for every point when the lamp distribution changes with angle.

Check the numbers

Point-to-Point Lighting Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Source height above horizontal plane = 3 m; Horizontal offset to target point = 2 m; Intensity toward that point = 1000 cd.

OutputComputed result
Direct horizontal illuminance64.003869 lux
Source-to-point distance3.605551 m
Angle from vertical33.690068 degrees

How one input changes the answer

ScenarioChanged inputResult
0.5 mHorizontal offset to target point106.637181 lux
1 mHorizontal offset to target point94.86833 lux
1.5 mHorizontal offset to target point79.504639 lux
2 mHorizontal offset to target point64.003869 lux
3 mHorizontal offset to target point39.28371 lux
4 mHorizontal offset to target point24 lux
6 mHorizontal offset to target point9.93808 lux

Unchanged inputs use: Source height above horizontal plane = 3 m; Horizontal offset to target point = 2 m; Intensity toward that point = 1000 cd. Results retain the model limitations described above.

Common questions

Can I add contributions from multiple fixtures?

Yes when each uses its own distance and correct directional intensity, with common measurement units. Reflected contributions require a separate model.

Does this implement DIALux parking calculations?

No. It is a direct single-source equation without IES/LDT import or a site geometry engine.

What angle should I read from the photometric table?

Use the source-to-point angle appropriate to the luminaire’s orientation. The reported vertical angle assumes the source axis is vertical.

Does this calculate glare or UGR?

No. UGR depends on observer and source geometry and cannot be converted directly from one lux value.

Which assumptions should I check?

Match the units, measurement plane and equipment boundary stated on this page. The starting values and comparison cases are chosen examples, not universal recommendations or current manufacturer ratings.

Where are the formula references?

Published references are listed at the bottom of this page as plain-text website addresses. The example tables are calculated from the displayed method rather than copied from proprietary tables.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • Australian Government: Lighting Manual, inverse-square and cosine lawshttps://www.energyrating.gov.au/sites/default/files/2022-12/Lighting%20Manual%20-%20Main%20Body%20-%20Final%20ex%20Appendices.pdf