Point-to-Point Lighting Calculator
An offset point is farther from the source and receives the ray obliquely. Combining inverse-square distance and cosine incidence gives I×height/d³ for a horizontal plane. The direction angle is reported so that the matching candela value can be selected from actual photometric data.
Your lighting inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Distance d = √(height²+offset²); horizontal E = I × height ÷ d³.
Calculate one luminaire’s direct horizontal illuminance contribution at an offset point.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
Intensity must correspond to the ray toward the point. This does not read an IES file, calculate reflections or complete a street/parking/sports lighting design.
Direct horizontal illuminance away from the fixture axis
An offset point is farther from the source and receives the ray obliquely. Combining inverse-square distance and cosine incidence gives I×height/d³ for a horizontal plane. The direction angle is reported so that the matching candela value can be selected from actual photometric data.
Outdoor, street, baseball field and parking-lot lighting normally involve several fixtures, glare constraints and defined grids. This single-point model is a building block, not a complete site design. Do not use peak center intensity for every point when the lamp distribution changes with angle.
Continue with: Lumens & Lux Calculator · Lux & Foot-Candle Converter · Lumens & Watts Calculator · Lighting Efficacy Calculator
Check the numbers
Point-to-Point Lighting Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Source height above horizontal plane = 3 m; Horizontal offset to target point = 2 m; Intensity toward that point = 1000 cd.
| Output | Computed result |
|---|---|
| Direct horizontal illuminance | 64.003869 lux |
| Source-to-point distance | 3.605551 m |
| Angle from vertical | 33.690068 degrees |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 0.5 m | Horizontal offset to target point | 106.637181 lux |
| 1 m | Horizontal offset to target point | 94.86833 lux |
| 1.5 m | Horizontal offset to target point | 79.504639 lux |
| 2 m | Horizontal offset to target point | 64.003869 lux |
| 3 m | Horizontal offset to target point | 39.28371 lux |
| 4 m | Horizontal offset to target point | 24 lux |
| 6 m | Horizontal offset to target point | 9.93808 lux |
Unchanged inputs use: Source height above horizontal plane = 3 m; Horizontal offset to target point = 2 m; Intensity toward that point = 1000 cd. Results retain the model limitations described above.
Common questions
Can I add contributions from multiple fixtures?
Yes when each uses its own distance and correct directional intensity, with common measurement units. Reflected contributions require a separate model.
Does this implement DIALux parking calculations?
No. It is a direct single-source equation without IES/LDT import or a site geometry engine.
What angle should I read from the photometric table?
Use the source-to-point angle appropriate to the luminaire’s orientation. The reported vertical angle assumes the source axis is vertical.
Does this calculate glare or UGR?
No. UGR depends on observer and source geometry and cannot be converted directly from one lux value.
Which assumptions should I check?
Match the units, measurement plane and equipment boundary stated on this page. The starting values and comparison cases are chosen examples, not universal recommendations or current manufacturer ratings.
Where are the formula references?
Published references are listed at the bottom of this page as plain-text website addresses. The example tables are calculated from the displayed method rather than copied from proprietary tables.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- Australian Government: Lighting Manual, inverse-square and cosine lawshttps://www.energyrating.gov.au/sites/default/files/2022-12/Lighting%20Manual%20-%20Main%20Body%20-%20Final%20ex%20Appendices.pdf