Lighting calculators / Light & unit conversions
Plan the light. Understand the numbers.
Lumens & Lux Calculator
Lumens measure luminous flux, while lux describes flux per square metre at a surface. The same 1,800 arriving lumens spread uniformly over 20 m² gives 90 lux; over 10 m² it gives 180 lux. The area and delivery boundary are essential, so there is no one-number lumen-to-lux conversion for every installation.
Your lighting inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Average lux = arriving lumens ÷ m²; arriving lumens = average lux × m².
Convert flux arriving on a surface to average illuminance, or find delivered lumens from area and lux.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
The flux must actually reach the stated area. A fixture’s rated lumens are not automatically delivered work-plane lumens.
Lumens per square metre and per square foot
Lumens measure luminous flux, while lux describes flux per square metre at a surface. The same 1,800 arriving lumens spread uniformly over 20 m² gives 90 lux; over 10 m² it gives 180 lux. The area and delivery boundary are essential, so there is no one-number lumen-to-lux conversion for every installation.
This tool also reports foot-candles, equivalent to arriving lumens per square foot. Foreign-language searches such as conversion lumens en lux or convertir lux en lumens refer to the same area relationship, but this page’s interface remains English. For a whole room, account for utilization and maintenance with the room lighting tools.
Continue with: Lux & Foot-Candle Converter · Lumens & Watts Calculator · Lighting Efficacy Calculator · Candela & Lumens Calculator
Check the numbers
Lumens & Lux Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Known luminous quantity = 1800 ; Area = 20 m²; Calculation direction = Lumens to lux.
| Output | Computed result |
|---|---|
| Average delivered illuminance | 90 lux |
| Illuminance | 90 lux |
| Illuminance / lumens per square foot | 8.361274 fc |
| Area | 20 m² |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 450 | Known luminous quantity | 22.5 lux |
| 900 | Known luminous quantity | 45 lux |
| 1350 | Known luminous quantity | 67.5 lux |
| 1800 | Known luminous quantity | 90 lux |
| 2700 | Known luminous quantity | 135 lux |
| 3600 | Known luminous quantity | 180 lux |
| 5400 | Known luminous quantity | 270 lux |
Unchanged inputs use: Known luminous quantity = 1800 ; Area = 20 m²; Calculation direction = Lumens to lux. Results retain the model limitations described above.
Common questions
Can you convert lumens to lux without area?
No. Lux is lumens per square metre, so the illuminated area is required.
How do I convert foot-candles to lumens?
Multiply foot-candles by square feet of illuminated area. Convert the units consistently before using this form.
Is lm/m² the same as lux?
Yes. One lux equals one lumen per square metre arriving at that plane.
Can I use total bulb lumens directly?
Only if all of that flux reaches the stated area. Room utilization, beam spill and obstructions otherwise need treatment.
How do lumens per foot differ from lumens per square foot?
Lumens per foot describes output per strip length, not illuminance. Multiply it by matching strip length for total lumens; lumens per square foot describes flux arriving per receiving area.
Which assumptions should I check?
Match the units, measurement plane and equipment boundary stated on this page. The starting values and comparison cases are chosen examples, not universal recommendations or current manufacturer ratings.
Where are the formula references?
Published references are listed at the bottom of this page as plain-text website addresses. The example tables are calculated from the displayed method rather than copied from proprietary tables.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- NIST SP 811 Appendix B.9: photometric unit conversionshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9
- UC Davis California Lighting Technology Center: High-Efficacy Residential Lighting, lumen method and room cavity ratiohttps://cltc.ucdavis.edu/sites/g/files/dgvnsk12206/files/media/documents/high-efficacy-residential-lighting-guide-dec14.pdf