Lighting CalculatorPlan light with clear assumptions

Lighting calculators / Screens & projectors

Plan the light. Understand the numbers.

Nine-Point Projector Flux Calculator

Measure representative points at the centers of nine equal-area image regions using a suitable illuminance meter and consistent image setup. Their arithmetic mean multiplied by total image area gives an approximate flux arriving on that plane. A central hot spot alone is not representative of the whole image.

Your lighting inputs

m²
lux
lux
lux
lux
lux
lux
lux
lux
lux

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Estimated image flux lm = arithmetic mean of nine equal-area grid readings in lux × image area m².

Calculate an image-flux estimate from nine illuminance readings and the corresponding screen area.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

This arithmetic does not certify ANSI or ISO testing. Grid placement, calibration, ambient subtraction, image setup and standard-specific procedures must be controlled separately.

Nine-point illuminance averages versus advertised projector brightness

Measure representative points at the centers of nine equal-area image regions using a suitable illuminance meter and consistent image setup. Their arithmetic mean multiplied by total image area gives an approximate flux arriving on that plane. A central hot spot alone is not representative of the whole image.

A measurement calculator cannot make an uncontrolled test into a standards-certified result. Account for ambient contribution and instrument response using the applicable procedure. The reported minimum-to-average reading ratio is only a summary of this grid and does not establish a projector’s full image quality.

Check the numbers

Nine-Point Projector Flux Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Projected image area = 4 m²; Illuminance reading 1 = 500 lux; Illuminance reading 2 = 500 lux; Illuminance reading 3 = 500 lux; Illuminance reading 4 = 500 lux; Illuminance reading 5 = 500 lux; Illuminance reading 6 = 500 lux; Illuminance reading 7 = 500 lux; Illuminance reading 8 = 500 lux; Illuminance reading 9 = 500 lux.

OutputComputed result
Nine-point image-flux estimate2,000 lm
Grid average500 lux
Grid minimum500 lux
Minimum / average1 ratio

How one input changes the answer

ScenarioChanged inputResult
1 m²Projected image area500 lm
2 m²Projected image area1,000 lm
3 m²Projected image area1,500 lm
4 m²Projected image area2,000 lm
6 m²Projected image area3,000 lm
8 m²Projected image area4,000 lm
12 m²Projected image area6,000 lm

Unchanged inputs use: Projected image area = 4 m²; Illuminance reading 1 = 500 lux; Illuminance reading 2 = 500 lux; Illuminance reading 3 = 500 lux; Illuminance reading 4 = 500 lux; Illuminance reading 5 = 500 lux; Illuminance reading 6 = 500 lux; Illuminance reading 7 = 500 lux; Illuminance reading 8 = 500 lux; Illuminance reading 9 = 500 lux. Results retain the model limitations described above.

Common questions

Does this produce certified ANSI lumens?

No. It demonstrates the nine-reading arithmetic. Standard-compliant setup and measurement must be established separately.

Why use nine readings rather than one?

A projected image can vary across its area, so one center reading may not represent its average.

Should I use luminance or illuminance readings?

The inputs here are illuminance in lux at the image plane, not screen luminance in nits.

Does it convert LED lumens to ANSI lumens?

No. It calculates from actual readings rather than an unsupported marketing-unit factor.

Which assumptions should I check?

Match the units, measurement plane and equipment boundary stated on this page. The starting values and comparison cases are chosen examples, not universal recommendations or current manufacturer ratings.

Where are the formula references?

Published references are listed at the bottom of this page as plain-text website addresses. The example tables are calculated from the displayed method rather than copied from proprietary tables.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • Konica Minolta: Language of Light, illuminance meters and nine-point projected fluxhttps://www.konicaminolta.com/instruments/knowledge/light/instrumentation/05.html