Lighting CalculatorPlan light with clear assumptions

Lighting calculators / Light & unit conversions

Plan the light. Understand the numbers.

Lux-Hours Calculator

Lux-hours integrate illuminance over a duration. At a constant 200 lux for eight hours, exposure is 1,600 lux-hours. If light changes over the day, add the lux-hours of each interval or use a correctly time-weighted average rather than a single peak reading.

Your lighting inputs

lux
hours

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Illuminance exposure = average lux × elapsed hours; lux-seconds = lux-hours × 3,600.

Calculate cumulative illuminance exposure for a constant or representative time-averaged light level.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Lux-hours do not encode UV content, spectral damage, plant photon dose or a conservation exposure limit.

Calculate cumulative light exposure over time

Lux-hours integrate illuminance over a duration. At a constant 200 lux for eight hours, exposure is 1,600 lux-hours. If light changes over the day, add the lux-hours of each interval or use a correctly time-weighted average rather than a single peak reading.

Museum exposure and light-sensitive material decisions require more information than the integrated photopic quantity. Spectrum, UV, material response and environmental conditions matter. Similarly, a plant-light daily light integral is measured in moles of photons per area, so it is not interchangeable with lux-hours.

Check the numbers

Lux-Hours Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Constant or time-averaged illuminance = 200 lux; Exposure duration = 8 hours.

OutputComputed result
Integrated illuminance exposure1,600 lux-hours
Same exposure5,760,000 lux-seconds

How one input changes the answer

ScenarioChanged inputResult
2 hoursExposure duration400 lux-hours
4 hoursExposure duration800 lux-hours
6 hoursExposure duration1,200 lux-hours
8 hoursExposure duration1,600 lux-hours
12 hoursExposure duration2,400 lux-hours
16 hoursExposure duration3,200 lux-hours
24 hoursExposure duration4,800 lux-hours

Unchanged inputs use: Constant or time-averaged illuminance = 200 lux; Exposure duration = 8 hours. Results retain the model limitations described above.

Common questions

How long does it take to reach 1.2 million lux-hours?

Divide 1,200,000 by the constant lux level. At 200 lux it takes 6,000 hours; this is arithmetic, not an exposure recommendation.

Can I add exposures from several days?

Yes, if they use matching units and the relevant surface measurements.

Is lux-hours the same as DLI?

No. DLI integrates photon flux, while lux-hours integrates human-vision-weighted illuminance.

Does this calculate time zones such as Lux to IST?

No. A Luxembourg time-zone query is unrelated to lighting exposure.

Which assumptions should I check?

Match the units, measurement plane and equipment boundary stated on this page. The starting values and comparison cases are chosen examples, not universal recommendations or current manufacturer ratings.

Where are the formula references?

Published references are listed at the bottom of this page as plain-text website addresses. The example tables are calculated from the displayed method rather than copied from proprietary tables.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • NIST SP 811 Appendix B.9: photometric unit conversionshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9
  • Apogee Instruments: Daily Light Integral, Measuring Light for Plantshttps://www.apogeeinstruments.com/daily-light-integral-measuring-light-for-plants/