Lighting CalculatorPlan light with clear assumptions

Lighting calculators / Light & unit conversions

Plan the light. Understand the numbers.

Candela & Lumens Calculator

Candela measures luminous intensity in a direction. Lumens measure flux integrated over solid angle. A narrow beam can have high center intensity with modest total flux, so a center-candela rating alone does not specify total lumens. This tool makes a uniform cone assumption so the geometric relationship can be explored.

Your lighting inputs

degrees

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Cone solid angle Ω = 2π[1−cos(full angle/2)]; uniform-cone lumens = candela × Ω.

Relate candela and luminous flux under an explicit uniform-intensity cone model.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

A real beam’s quoted 50% beam angle does not make it a uniform cone. Integrate actual intensity data for reliable total lumens; 4π×cd applies only to isotropic intensity.

Candlepower, beam angle and total luminous flux

Candela measures luminous intensity in a direction. Lumens measure flux integrated over solid angle. A narrow beam can have high center intensity with modest total flux, so a center-candela rating alone does not specify total lumens. This tool makes a uniform cone assumption so the geometric relationship can be explored.

When the full cone reaches 360 degrees, the solid angle is 4π steradians and the model becomes isotropic. Most lamps and LEDs have nonuniform intensity distributions, and quoted beam angles often describe a percentage of peak intensity rather than a hard cutoff. Manufacturer IES/LDT data is needed for actual integration.

Check the numbers

Candela & Lumens Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Known luminous quantity = 1000 ; Full uniform-cone angle = 60 degrees; Calculation direction = Candela to lumens.

OutputComputed result
Uniform-cone result841.787214 lm
Cone solid angle0.841787 sr
Uniform full-sphere fraction6.69873 %

How one input changes the answer

ScenarioChanged inputResult
15 degreesFull uniform-cone angle53.753521 lm
30 degreesFull uniform-cone angle214.094348 lm
45 degreesFull uniform-cone angle478.279003 lm
60 degreesFull uniform-cone angle841.787214 lm
90 degreesFull uniform-cone angle1,840.302369 lm
120 degreesFull uniform-cone angle3,141.592654 lm
180 degreesFull uniform-cone angle6,283.185307 lm

Unchanged inputs use: Known luminous quantity = 1000 ; Full uniform-cone angle = 60 degrees; Calculation direction = Candela to lumens. Results retain the model limitations described above.

Common questions

Can I convert candlepower to lumens by multiplying by 12.57?

Only for intensity that is uniform in every direction. A flashlight center-candela figure does not meet that assumption.

How do I use millicandela?

Divide mcd by 1,000 to obtain candela before entering the forward calculation.

Does a 60 degree beam emit uniform intensity?

Usually not. A published beam angle normally has a measurement definition, so this model is an illustration rather than a product test.

Can I convert candela to inches?

No. Intensity and distance are different quantities. A distance calculation also needs a target illuminance and geometric assumptions.

Which assumptions should I check?

Match the units, measurement plane and equipment boundary stated on this page. The starting values and comparison cases are chosen examples, not universal recommendations or current manufacturer ratings.

Where are the formula references?

Published references are listed at the bottom of this page as plain-text website addresses. The example tables are calculated from the displayed method rather than copied from proprietary tables.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • NIST: Realization of the candela and photometric spectral weightinghttps://www.nist.gov/pml/sensor-science/optical-radiation/realization-candela
  • Australian Government: Lighting Manual, inverse-square and cosine lawshttps://www.energyrating.gov.au/sites/default/files/2022-12/Lighting%20Manual%20-%20Main%20Body%20-%20Final%20ex%20Appendices.pdf