Lighting Uniformity Calculator

A lighting uniformity calculation must state its denominator. Minimum divided by average differs from minimum divided by maximum, even for the same readings. This tool displays both so that reports using different conventions are not compared as though their ratios were identical.

Your lighting inputs

lux
lux
lux
lux
lux

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Average = arithmetic mean of five equal-weight readings; U₀ = minimum/average; min/max = minimum/maximum.

Summarize five illuminance readings with minimum, maximum, mean and two clearly labeled uniformity ratios.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

Readings must represent the same plane and equal-weight sampling areas. This five-point summary does not establish a standards-compliant measurement grid.

Read a lighting report without confusing uniformity ratios

A lighting uniformity calculation must state its denominator. Minimum divided by average differs from minimum divided by maximum, even for the same readings. This tool displays both so that reports using different conventions are not compared as though their ratios were identical.

The sample readings are illustrative, not acceptable limits for an office, road or sports field. Select a proper grid and measurement procedure for the application. Unequally spaced samples may need area weighting, and a small group of favorable points can miss the actual minimum.

Check the numbers

Lighting Uniformity Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Grid reading 1 = 250 lux; Grid reading 2 = 300 lux; Grid reading 3 = 280 lux; Grid reading 4 = 320 lux; Grid reading 5 = 350 lux.

OutputComputed result
Minimum / average uniformity0.833333 ratio
Average300 lux
Minimum250 lux
Maximum350 lux
Minimum / maximum0.714286 ratio

How one input changes the answer

ScenarioChanged inputResult
62.5 luxGrid reading 10.238095 ratio
125 luxGrid reading 10.454545 ratio
187.5 luxGrid reading 10.652174 ratio
250 luxGrid reading 10.833333 ratio
375 luxGrid reading 10.861538 ratio
500 luxGrid reading 10.8 ratio
750 luxGrid reading 10.7 ratio

Unchanged inputs use: Grid reading 1 = 250 lux; Grid reading 2 = 300 lux; Grid reading 3 = 280 lux; Grid reading 4 = 320 lux; Grid reading 5 = 350 lux. Results retain the model limitations described above.

Common questions

What is U₀ in this calculator?

It is minimum illuminance divided by the arithmetic average of the five readings.

Is minimum/maximum the same as minimum/average?

No. Check the specified ratio before comparing a result with a requirement.

What happens if all readings are zero?

A uniformity ratio would divide zero by zero, so the calculator rejects that case.

Does this verify lighting compliance?

No. The applicable sampling grid, maintained condition, uniformity definition and required limits must be established separately.

Which assumptions should I check?

Match the units, measurement plane and equipment boundary stated on this page. The starting values and comparison cases are chosen examples, not universal recommendations or current manufacturer ratings.

Where are the formula references?

Published references are listed at the bottom of this page as plain-text website addresses. The example tables are calculated from the displayed method rather than copied from proprietary tables.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • Australian Government: Lighting Manual, inverse-square and cosine lawshttps://www.energyrating.gov.au/sites/default/files/2022-12/Lighting%20Manual%20-%20Main%20Body%20-%20Final%20ex%20Appendices.pdf
  • UC Davis California Lighting Technology Center: High-Efficacy Residential Lighting, lumen method and room cavity ratiohttps://cltc.ucdavis.edu/sites/g/files/dgvnsk12206/files/media/documents/high-efficacy-residential-lighting-guide-dec14.pdf