Lighting calculators / Light & unit conversions
Plan the light. Understand the numbers.
Light Distance Calculator
Doubling distance gives one quarter of the original illuminance in a valid inverse-square model. Tripling distance gives one ninth. This describes a geometric change from a known reading; it does not require guessing the lamp’s total lumens.
Your lighting inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
E₂ = E₁ × (distance₁/distance₂)² for the same direction and orientation.
Estimate relative illuminance change with distance under a point-source inverse-square model.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
Keep source output, direction and receiver orientation fixed. Near-field panels, optical focusing, reflections and intervening media can invalidate this scaling.
Relative light intensity and inverse-square examples
Doubling distance gives one quarter of the original illuminance in a valid inverse-square model. Tripling distance gives one ninth. This describes a geometric change from a known reading; it does not require guessing the lamp’s total lumens.
For a controlled biology or physics demonstration, keep the sensor angle and lamp settings fixed and measure ambient light separately. A relative illuminance prediction is not automatically a prediction of biological response, photosynthesis or camera exposure because spectrum and the receiving system also matter.
Continue with: Lumens & Lux Calculator · Lux & Foot-Candle Converter · Lumens & Watts Calculator · Lighting Efficacy Calculator
Check the numbers
Light Distance Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Illuminance at first distance = 500 lux; First distance = 1 m; New distance = 2 m.
| Output | Computed result |
|---|---|
| Inverse-square illuminance | 125 lux |
| Relative to first reading | 25 % |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 0.5 m | New distance | 2,000 lux |
| 1 m | New distance | 500 lux |
| 1.5 m | New distance | 222.222222 lux |
| 2 m | New distance | 125 lux |
| 3 m | New distance | 55.555556 lux |
| 4 m | New distance | 31.25 lux |
| 6 m | New distance | 13.888889 lux |
Unchanged inputs use: Illuminance at first distance = 500 lux; First distance = 1 m; New distance = 2 m. Results retain the model limitations described above.
Common questions
What is the equation for relative light intensity?
For a valid point-source comparison, the ratio E₂/E₁ is (d₁/d₂)².
Why do measurements differ from the inverse-square result?
Check ambient light, reflections, sensor orientation, near-field source size and directional output.
Does half the distance mean twice the light?
In the ideal model it means four times the illuminance, not twice.
Can this find lux from a watt rating?
No. An electrical watt rating needs photometric output and geometry before it determines surface illuminance.
Which assumptions should I check?
Match the units, measurement plane and equipment boundary stated on this page. The starting values and comparison cases are chosen examples, not universal recommendations or current manufacturer ratings.
Where are the formula references?
Published references are listed at the bottom of this page as plain-text website addresses. The example tables are calculated from the displayed method rather than copied from proprietary tables.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- Australian Government: Lighting Manual, inverse-square and cosine lawshttps://www.energyrating.gov.au/sites/default/files/2022-12/Lighting%20Manual%20-%20Main%20Body%20-%20Final%20ex%20Appendices.pdf