General Lighting Load Calculator

A floor-area load allowance is a design or code input, while measured connected watts describes actual equipment power. Do not substitute one for the other without understanding the required method. If a schedule gives VA/ft², multiply it by 10.7639104167 to obtain VA/m² before using this form.

Your lighting inputs

m²
VA/m²
V

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Apparent load VA = area m² × selected VA/m²; single-phase equivalent current = VA ÷ V.

Calculate a floor-area lighting load from a user-supplied apparent-power density.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

The starting density is illustrative, not an NEC value. Demand factors, socket/receptacle allowances, dwelling rules and 2020/2023/2026 code editions are not selected automatically.

Dwelling and commercial lighting-load arithmetic

A floor-area load allowance is a design or code input, while measured connected watts describes actual equipment power. Do not substitute one for the other without understanding the required method. If a schedule gives VA/ft², multiply it by 10.7639104167 to obtain VA/m² before using this form.

NEC dwelling lighting load queries can depend on the adopted edition, floor-area definition, receptacle provisions and demand treatment. This page intentionally accepts the verified density rather than presenting an unverified number as universal. The simple current output assumes single-phase voltage and is not a conductor or overcurrent-protection design.

Check the numbers

General Lighting Load Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Area = 20 m²; Selected load density = 30 VA/m²; Supply voltage for simple current estimate = 230 V.

OutputComputed result
Area-based apparent lighting load600 VA
Simple single-phase equivalent current2.608696 A
Selected density30 VA/m²

How one input changes the answer

ScenarioChanged inputResult
5 m²Area150 VA
10 m²Area300 VA
15 m²Area450 VA
20 m²Area600 VA
30 m²Area900 VA
40 m²Area1,200 VA
60 m²Area1,800 VA

Unchanged inputs use: Area = 20 m²; Selected load density = 30 VA/m²; Supply voltage for simple current estimate = 230 V. Results retain the model limitations described above.

Common questions

Does the tool include the 2026 NEC lighting allowance?

No. It does not embed edition-specific legal requirements; enter a value verified for the applicable adopted method.

Can I calculate socket and lighting points?

Not automatically. Fixture count, receptacle requirements and circuit arrangement are separate questions.

Is apparent load in VA the same as watts?

Not generally. Watts are real input power, while VA is apparent power.

Does dividing by voltage size the circuit?

No. It gives a simplified equivalent current. Demand, continuous loading, wiring and protection requirements remain separate.

Which assumptions should I check?

Match the units, measurement plane and equipment boundary stated on this page. The starting values and comparison cases are chosen examples, not universal recommendations or current manufacturer ratings.

Where are the formula references?

Published references are listed at the bottom of this page as plain-text website addresses. The example tables are calculated from the displayed method rather than copied from proprietary tables.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • NIST SP 811 Appendix B.9: photometric unit conversionshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9
  • UC Davis California Lighting Technology Center: High-Efficacy Residential Lighting, lumen method and room cavity ratiohttps://cltc.ucdavis.edu/sites/g/files/dgvnsk12206/files/media/documents/high-efficacy-residential-lighting-guide-dec14.pdf