Lighting calculators / Light & unit conversions
Plan the light. Understand the numbers.
Candela & Lux Calculator
A 1,000 cd source produces 250 lux at two metres on a surface perpendicular to the ray in this ideal model. At four metres it gives one quarter as much illuminance. Tilting the receiving surface reduces the intercepted light through the cosine factor.
Your lighting inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Illuminance E = I × cos(incidence angle) ÷ distance².
Apply inverse-square and cosine laws for a sufficiently small source with known intensity toward the point.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
This far-field point-source approximation ignores reflections and attenuation. The angle is relative to the receiving surface normal, not automatically the lamp beam angle.
Light intensity, distance and surface orientation
A 1,000 cd source produces 250 lux at two metres on a surface perpendicular to the ray in this ideal model. At four metres it gives one quarter as much illuminance. Tilting the receiving surface reduces the intercepted light through the cosine factor.
The inverse-square law is a useful GCSE and physics relationship only when its assumptions fit. Extended luminous panels at close range, reflected rooms and directional lamps viewed at different beam angles can depart from the simple scaling. Use intensity toward the actual point, not a center value that belongs to another direction.
Continue with: Lumens & Lux Calculator · Lux & Foot-Candle Converter · Lumens & Watts Calculator · Lighting Efficacy Calculator
Check the numbers
Candela & Lux Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Known luminous quantity = 1000 ; Source-to-surface distance = 2 m; Incidence angle from surface normal = 0 degrees; Calculation direction = Candela to lux.
| Output | Computed result |
|---|---|
| Point-source geometric result | 250 lux |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 0.5 m | Source-to-surface distance | 4,000 lux |
| 1 m | Source-to-surface distance | 1,000 lux |
| 1.5 m | Source-to-surface distance | 444.444444 lux |
| 2 m | Source-to-surface distance | 250 lux |
| 3 m | Source-to-surface distance | 111.111111 lux |
| 4 m | Source-to-surface distance | 62.5 lux |
| 6 m | Source-to-surface distance | 27.777778 lux |
Unchanged inputs use: Known luminous quantity = 1000 ; Source-to-surface distance = 2 m; Incidence angle from surface normal = 0 degrees; Calculation direction = Candela to lux. Results retain the model limitations described above.
Common questions
How do I convert mcd to lux?
First convert millicandela to candela by dividing by 1,000, then apply distance and incidence geometry.
Is lux the same as source intensity?
No. Lux measures illuminance on a surface; candela is source intensity in a direction.
Can I use this for plant or biology experiments?
It can illustrate geometry, but lux is human-vision weighted and does not directly quantify plant photon flux. Spectrum and measurement conditions matter.
Does this include other lamps in the room?
No. Add separately calculated contributions only when the individual assumptions remain valid.
Can I convert lux to camera exposure value (EV)?
An exposure conversion needs the meter calibration convention and ISO basis. This page calculates illuminance geometry; it does not implement EV calibration or a camera exposure recommendation.
Which assumptions should I check?
Match the units, measurement plane and equipment boundary stated on this page. The starting values and comparison cases are chosen examples, not universal recommendations or current manufacturer ratings.
Where are the formula references?
Published references are listed at the bottom of this page as plain-text website addresses. The example tables are calculated from the displayed method rather than copied from proprietary tables.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- Australian Government: Lighting Manual, inverse-square and cosine lawshttps://www.energyrating.gov.au/sites/default/files/2022-12/Lighting%20Manual%20-%20Main%20Body%20-%20Final%20ex%20Appendices.pdf
- NIST: Realization of the candela and photometric spectral weightinghttps://www.nist.gov/pml/sensor-science/optical-radiation/realization-candela