Lighting CalculatorPlan light with clear assumptions

Lighting calculators / Light & unit conversions

Plan the light. Understand the numbers.

Beam Angle & Diameter Calculator

A full beam angle spans both sides of the optical axis. The tangent formula uses half that angle to obtain the footprint radius. The entered throw is the perpendicular distance to the plane, so a tilted luminaire or sloping surface can create an elliptical rather than circular footprint.

Your lighting inputs

m
degrees

Starting values are illustrative. Check units and assumptions below. Calculate submits your inputs to this site’s result page.

Reset

Your result

Ready to calculate

Enter your values and press Calculate. The result will open on the calculation page.

Published references · Clear assumptions · No sign-up

The method

Formula and calculation steps

Beam diameter = 2 × throw distance × tan(full beam angle/2); area = π × (diameter/2)².

Calculate a geometric circular beam diameter and footprint area on a perpendicular plane.

  1. Choose a measurement plane and use compatible units for all inputs.
  2. Obtain appropriate product data or representative measurements for the stated model.
  3. Submit the form, then interpret the result with the assumptions and limits below.

The quoted beam angle has a product-specific intensity definition. The circular footprint model excludes tilt, beam tails, obstructions and photometric uniformity.

LED spotlight beams, downlight coverage and throw

A full beam angle spans both sides of the optical axis. The tangent formula uses half that angle to obtain the footprint radius. The entered throw is the perpendicular distance to the plane, so a tilted luminaire or sloping surface can create an elliptical rather than circular footprint.

Coverage geometry is not a proof that adjacent beams produce a uniform room. A 50%-intensity beam edge still has light outside it, and the interior is not generally uniform. Radar and ultrasonic beam queries use related geometry but require their own frequency and field assumptions, which this lighting tool does not model.

Check the numbers

Beam Angle & Diameter Calculator: calculated examples

These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.

Worked example with stated inputs

Perpendicular throw distance = 3 m; Full beam angle = 60 degrees.

OutputComputed result
Geometric beam diameter3.464102 m
Circular footprint area9.424778 m²
Radius1.732051 m

How one input changes the answer

ScenarioChanged inputResult
0.75 mPerpendicular throw distance0.866025 m
1.5 mPerpendicular throw distance1.732051 m
2.25 mPerpendicular throw distance2.598076 m
3 mPerpendicular throw distance3.464102 m
4.5 mPerpendicular throw distance5.196152 m
6 mPerpendicular throw distance6.928203 m
9 mPerpendicular throw distance10.392305 m

Unchanged inputs use: Perpendicular throw distance = 3 m; Full beam angle = 60 degrees. Results retain the model limitations described above.

Common questions

Is beam angle a half angle?

The input here is the full angle. The equation divides it by two internally.

Can I use it to choose recessed light spacing?

It shows approximate geometric coverage, but actual spacing should use photometric data and any manufacturer criterion.

What if the beam hits at an angle?

The simple circular footprint no longer applies. This form assumes a perpendicular receiving plane.

Does the footprint have constant lux?

No. A geometric diameter does not describe the intensity profile or uniformity.

Which assumptions should I check?

Match the units, measurement plane and equipment boundary stated on this page. The starting values and comparison cases are chosen examples, not universal recommendations or current manufacturer ratings.

Where are the formula references?

Published references are listed at the bottom of this page as plain-text website addresses. The example tables are calculated from the displayed method rather than copied from proprietary tables.

Formula sources and references

References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.

  • Australian Government: Lighting Manual, inverse-square and cosine lawshttps://www.energyrating.gov.au/sites/default/files/2022-12/Lighting%20Manual%20-%20Main%20Body%20-%20Final%20ex%20Appendices.pdf