Lighting calculators / Rooms & layouts
Plan the light. Understand the numbers.
Room Cavity Ratio Calculator
Room cavity ratio describes the proportions of the cavity between luminaires and the working plane. Keep length, width and height in the same unit. It is dimensionless, so converting all three consistently from feet to metres does not change the ratio.
Your lighting inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
RCR = 5 × cavity height × (length + width) ÷ (length × width).
Calculate room cavity ratio to help select a coefficient of utilization from appropriate luminaire data.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
RCR does not determine CU by itself. Surface reflectances, distribution and the manufacturer’s tabulation are still required.
Use room geometry without inventing a utilization coefficient
Room cavity ratio describes the proportions of the cavity between luminaires and the working plane. Keep length, width and height in the same unit. It is dimensionless, so converting all three consistently from feet to metres does not change the ratio.
Once RCR is known, consult the relevant product’s coefficient-of-utilization information with the correct ceiling and wall reflectances. This tool does not supply proprietary CU tables or substitute a generic coefficient for every room. Higher walls and a narrow room can alter utilization even when floor area is unchanged.
Continue with: Room Lighting Calculator · Average Room Lux Calculator · Recessed Lighting Layout Calculator · Lighting Spacing Criterion Calculator
Check the numbers
Room Cavity Ratio Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Room length = 5 m; Room width = 4 m; Luminaire-to-workplane height = 2.5 m.
| Output | Computed result |
|---|---|
| Room cavity ratio | 5.625 ratio |
| Working-plane area | 20 m² |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 0.625 m | Luminaire-to-workplane height | 1.40625 ratio |
| 1.25 m | Luminaire-to-workplane height | 2.8125 ratio |
| 1.875 m | Luminaire-to-workplane height | 4.21875 ratio |
| 2.5 m | Luminaire-to-workplane height | 5.625 ratio |
| 3.75 m | Luminaire-to-workplane height | 8.4375 ratio |
| 5 m | Luminaire-to-workplane height | 11.25 ratio |
| 7.5 m | Luminaire-to-workplane height | 16.875 ratio |
Unchanged inputs use: Room length = 5 m; Room width = 4 m; Luminaire-to-workplane height = 2.5 m. Results retain the model limitations described above.
Common questions
What height goes into RCR?
Use the vertical distance from the luminaire plane to the selected working plane.
Can I calculate CU from RCR automatically?
Not reliably without product distribution and surface reflectance information. This tool deliberately does not guess a CU.
Is RCR measured in metres?
No. It is dimensionless. The dimensions inside the equation must simply share a unit.
Can I use this for an irregular room?
A single rectangle may not represent complex geometry. Divide or model the space with an appropriate photometric method.
Which assumptions should I check?
Match the units, measurement plane and equipment boundary stated on this page. The starting values and comparison cases are chosen examples, not universal recommendations or current manufacturer ratings.
Where are the formula references?
Published references are listed at the bottom of this page as plain-text website addresses. The example tables are calculated from the displayed method rather than copied from proprietary tables.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- UC Davis California Lighting Technology Center: High-Efficacy Residential Lighting, lumen method and room cavity ratiohttps://cltc.ucdavis.edu/sites/g/files/dgvnsk12206/files/media/documents/high-efficacy-residential-lighting-guide-dec14.pdf