Photometry and radiometry weight optical energy differently. A lux measurement cannot determine total radiant energy without knowing the spectrum or a justified luminous efficacy of radiation. The relevant factor uses radiant watts, not electricity purchased at the lamp input.
Your lighting inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Radiant irradiance W/m² = lux ÷ spectral luminous efficacy lm/radiant W.
Relate photopic illuminance and radiant irradiance using an explicitly supplied spectral weighting factor.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
The 683 example is the SI photometric reference-frequency case, not electrical lamp efficacy or a universal sunlight/LED factor. UV and IR can have negligible photopic response.
Why lux-to-W/m² needs a spectrum
Photometry and radiometry weight optical energy differently. A lux measurement cannot determine total radiant energy without knowing the spectrum or a justified luminous efficacy of radiation. The relevant factor uses radiant watts, not electricity purchased at the lamp input.
The reference value of 683 lm/W applies at the defined photometric reference frequency. A broad-spectrum light has a different factor, and radiation outside the visible response can contribute energy without comparable lux. This model cannot recover UV, IR or a complete spectrum from one illuminance number.
Continue with: Lux & PPFD Calculator · PPFD to DLI Calculator · PPFD & Delivered Photon Flux Calculator · Room Lighting Calculator
Check the numbers
Lux & Radiant Irradiance Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Known light quantity = 683 ; Spectral luminous efficacy of radiation = 683 lm/radiant W; Calculation direction = Lux to radiant W/m².
| Output | Computed result |
|---|---|
| Spectrum-factor conversion | 1 radiant W/m² |
| Assumed spectral efficacy | 683 lm/radiant W |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 170.75 | Known light quantity | 0.25 radiant W/m² |
| 341.5 | Known light quantity | 0.5 radiant W/m² |
| 512.25 | Known light quantity | 0.75 radiant W/m² |
| 683 | Known light quantity | 1 radiant W/m² |
| 1024.5 | Known light quantity | 1.5 radiant W/m² |
| 1366 | Known light quantity | 2 radiant W/m² |
| 2049 | Known light quantity | 3 radiant W/m² |
Unchanged inputs use: Known light quantity = 683 ; Spectral luminous efficacy of radiation = 683 lm/radiant W; Calculation direction = Lux to radiant W/m². Results retain the model limitations described above.
Common questions
Can I use an LED’s 100 lm/W wall-input efficacy?
Not here. Electrical efficacy includes conversion and driver losses; this conversion needs efficacy per radiant watt.
Does 683 lux always mean 1 W/m²?
Only under the specified reference spectral factor. It is not a universal relation for all lights.
Can I convert lux directly to lamp electrical watts?
No. Area, optical spectrum, delivered fraction and electrical conversion efficiency are additional requirements.
Can this estimate UV exposure from lux?
No. Lux is not a UV exposure meter and does not encode the required spectral information.
Which assumptions should I check?
Match the units, measurement plane and equipment boundary stated on this page. The starting values and comparison cases are chosen examples, not universal recommendations or current manufacturer ratings.
Where are the formula references?
Published references are listed at the bottom of this page as plain-text website addresses. The example tables are calculated from the displayed method rather than copied from proprietary tables.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- NIST: Realization of the candela and photometric spectral weightinghttps://www.nist.gov/pml/sensor-science/optical-radiation/realization-candela
- NIST SP 811 Appendix B.9: photometric unit conversionshttps://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b9