Lighting calculators / Plant light & exposure
Plan the light. Understand the numbers.
Lux & PPFD Calculator
Lux is weighted for human photopic vision, while PPFD counts photons within a defined spectral range per area per second. Two spectra can produce the same lux but different PPFD. A suitable spectrum-specific factor is therefore essential; a lamp’s color temperature by itself does not establish it.
Your lighting inputs
Your result
Ready to calculateEnter your values and press Calculate. The result will open on the calculation page.
Published references · Clear assumptions · No sign-up
The method
Formula and calculation steps
Estimated PPFD = lux ÷ source-specific lux-per-PPFD factor; lux = PPFD × factor.
Convert lux and photon flux density only when a justified source-spectrum conversion factor is supplied.
- Choose a measurement plane and use compatible units for all inputs.
- Obtain appropriate product data or representative measurements for the stated model.
- Submit the form, then interpret the result with the assumptions and limits below.
The example factor 54 is Apogee’s published approximate sunlight factor. It is not a universal white-LED, RGB, aquarium or grow-light factor.
Plant-light lux, PAR and photon measurements
Lux is weighted for human photopic vision, while PPFD counts photons within a defined spectral range per area per second. Two spectra can produce the same lux but different PPFD. A suitable spectrum-specific factor is therefore essential; a lamp’s color temperature by itself does not establish it.
For LED planted aquariums or horticulture, use the actual spectral information or a suitable quantum sensor. Published factors for one lamp family must not be copied to every product with a similar color label. This page performs the chosen-factor conversion and does not diagnose plant health or recommend a crop-specific light target.
Continue with: PPFD to DLI Calculator · PPFD & Delivered Photon Flux Calculator · Lux & Radiant Irradiance Calculator · Room Lighting Calculator
Check the numbers
Lux & PPFD Calculator: calculated examples
These are computed scenarios using the same server calculation as the form. They are not manufacturer ratings or prescribed design values.
Worked example with stated inputs
Known light quantity = 5400 ; Source-specific lux per µmol/m²/s = 54 lux per PPFD; Calculation direction = Lux to PPFD.
| Output | Computed result |
|---|---|
| Source-factor conversion | 100 µmol/m²/s |
| Assumed conversion factor | 54 lux per µmol/m²/s |
How one input changes the answer
| Scenario | Changed input | Result |
|---|---|---|
| 1350 | Known light quantity | 25 µmol/m²/s |
| 2700 | Known light quantity | 50 µmol/m²/s |
| 4050 | Known light quantity | 75 µmol/m²/s |
| 5400 | Known light quantity | 100 µmol/m²/s |
| 8100 | Known light quantity | 150 µmol/m²/s |
| 10800 | Known light quantity | 200 µmol/m²/s |
| 16200 | Known light quantity | 300 µmol/m²/s |
Unchanged inputs use: Known light quantity = 5400 ; Source-specific lux per µmol/m²/s = 54 lux per PPFD; Calculation direction = Lux to PPFD. Results retain the model limitations described above.
Common questions
Can I convert lux to PAR with one universal multiplier?
No. PAR is a spectral concept, and PPFD estimation from lux requires source-spectrum information.
Is the default factor correct for my LED?
Not necessarily. The 54 example is approximate sunlight, not a generic LED calibration.
Can I convert lumens to PPFD?
First establish delivered illuminance over an area and an appropriate spectral factor, or use direct photon measurements. Fixture lumens alone are insufficient.
Does a phone lux reading guarantee accurate PPFD?
No. Sensor spectral response, geometry and calibration introduce additional uncertainty.
Which assumptions should I check?
Match the units, measurement plane and equipment boundary stated on this page. The starting values and comparison cases are chosen examples, not universal recommendations or current manufacturer ratings.
Where are the formula references?
Published references are listed at the bottom of this page as plain-text website addresses. The example tables are calculated from the displayed method rather than copied from proprietary tables.
Related calculators
Formula sources and references
References support the underlying methods and units. Chosen example inputs are not universal recommendations, current tariffs or proprietary test results.
- Apogee Instruments: PPFD to Lux Conversion; source-spectrum dependencehttps://www.apogeeinstruments.com/conversion-ppfd-to-lux/
- NIST: Realization of the candela and photometric spectral weightinghttps://www.nist.gov/pml/sensor-science/optical-radiation/realization-candela